Skip to main content

Table 3 Electrochemical parameters and corrosion rates obtained by polarization and immersion testing

From: Optimization of the clinically approved Mg-Zn alloy system through the addition of Ca

Materials

Corrosion potential (V)

Corrosion density (μ A/cm2)

Polarization (mm/y)

Immersion (mm/y)

P-Mg

− 1.59

14

0.32

0.103

2%Zn

−1.44

4.4

0.10

0.064

0.1%Ca

−1.49

4.9

0.11

0.095

0.3%Ca

−1.62

17

0.39

0.172