Skip to main content

Table 1 Tensile strength and modulus of PDMS materials

From: Broad spectrum antimicrobial PDMS-based biomaterial for catheter fabrication

Materials

Modulus (Automatic Young’s) [MPa]

Maximum Force [N]

Tensile stress at Maximum Force [MPa]

As synthesized

PDMS

1.78 ± 0.35

13.83 ± 1.94

0.51 ± 0.07

PDMS-PIM1

1.38 ± 0.38

10.30 ± 2.34

0.37 ± 0.11

PDMS-PIM5

1.11 ± 0.28

10.39 ± 1.55

0.37 ± 0.04

45 Days of Microbial Exposure

PDMS

1.79 ± 0.06

14.13 ± 4.20

0.43 ± 0.13

PDMS-PIM1

1.78 ± 0.25

11.73 ± 1.73

0.36 ± 0.06

PDMS-PIM5

1.31 ± 0.20

13.34 ± 2.64

0.42 ± 0.07

60 Days of Microbial Exposure

PDMS

1.91 ± 0.02

14.83 ± 2.06

0.40 ± 0.05

PDMS-PIM1

1.76 ± 0.45

11.24 ± 1.06

0.39 ± 0.03

PDMS-PIM5

1.28 ± 0.09

10.27 ± 2.28

0.39 ± 0.03